The fastest way to get a clean shop drawing set is not to rush the designer. It's to hand them a complete package on day one.
Missing backgrounds, a stale flow test, or a hazard that's still a guess show up later as RFIs, redraws, and AHJ comments. That eats schedule. On a bid, it can also change the pipe and the price.
This is the handoff list we ask contractors and estimators to send with a job. You don't need every item on every project. Send what you have, note what you don't, and the design can start on solid ground.
Start with current backgrounds
Architectural, structural, and MEP files
Send the current architectural, structural, and MEP sets, not last month's issue. Native CAD or Revit files are best, along with PDFs. Include the software and version (AutoCAD, Revit, and the year), the scale, and whether the files are 2D or 3D. If updates are still coming, say how revisions will arrive.
Why it matters: A designer tracing an outdated floor plan will miss moved walls, new shafts, and beam sizes.
Ceiling heights and obstructions
Include reflected ceiling plans, finished ceiling heights, soffits, clouds, and hard lids. Call out known obstructions: duct mains, cable trays, skylights, unit heaters, and structural steel. If ceilings aren't defined yet, say so, and note exposed structure or mezzanines.
Why it matters: Head placement and deflector distance are only as accurate as the ceiling and whatever sits in the way. A missed duct run or deep beam leads to field relocations and extra fittings.
Existing systems on tenant improvements
For TIs, renovations, or additions, send as-builts, the latest approved shop drawings, hydraulic calculations, and photos if you have them. Spell out what stays, what comes out, and what has to remain in service. If the hazard or occupancy is changing, say so. If existing conditions are unknown or the as-builts aren't reliable, we can send someone out for a site survey and field verification.
Why it matters: Tying into a system you can't see is how you get undersized mains, surprise backflow requirements, and heads that no longer match the ceiling.
Design to the code the AHJ will enforce
NFPA edition and local amendments
Tell us whether the job is NFPA 13, 13R, or 13D, and which edition the authority having jurisdiction has adopted. If the city or county has local amendments, a design bulletin, or a preferred notes sheet, include those too. Specs and the architectural code sheet aren't always what plan review will enforce.
Why it matters: Head spacing, hanger rules, seismic bracing, and calculation criteria all shift by edition and by jurisdiction. Designing to the wrong book is a common reason a set comes back marked up. For a complete permit set, see our fire sprinkler design and permit packages.
Occupancy, hazard classification, and storage
State the occupancy and the hazard classification you are designing to, or flag it if it hasn't been confirmed. For storage occupancies, send commodity classification, storage height, aisle widths, rack type, encapsulation, and whether there are solid shelves, flue spaces, or in-rack sprinklers. If the architect's code sheet and the owner's use of the space don't match, raise that early.
Why it matters: Hazard and commodity drive density, hose allowance, and often the head type. A "light hazard office" that is actually storage will not calculate correctly or pass review.
AHJ and insurance requirements
Name the AHJ and any other reviewers: fire marshal, building department, third-party plan review, or the engineer of record. If the building is under FM Global or another insurer with its own data sheets, include those requirements. Note whether the AHJ wants Tier 1 permit plans or full specification shop drawings.
Why it matters: FM Global and some AHJs require things NFPA alone does not. Finding that out after the first submittal means a redesign and a lost week.
Send a water supply the calcs can trust
Send a recent hydrant flow test with static pressure, residual pressure, flow in gpm, the date of the test, and the location of the hydrant or test point relative to the building. If a fire pump, tank, or pressure-reducing valve is part of the supply, include the cut sheets and any existing pump test data. If you don't have a current test, tell us what you do have, including any assumed pressures used in the bid.
Why it matters: Hydraulic calculations are only as good as the supply they are run against. An old test or a missing residual can make a system look like it works on paper and fail in the field, or lead to oversized pipe and a high material bid.
Draw it the way your shop builds
Pipe, fittings, heads, and fab standards
Tell us your preferred pipe, fittings, hangers, and sprinkler heads, including manufacturers if you have a standard. Send your fab shop standards: grooved versus threaded, cut lengths, make-up, piece-numbering, and how you want floors or areas broken out. If you have a title block and CAD standards, send those so the set looks like it came from your office.
Why it matters: A set drawn with fittings that aren't on the truck, or stocklisted in a format your shop doesn't use, gets redrawn before it hits the fab line.
BIM and level of development
If the project is in BIM, send the BIM execution plan, the required level of development, the coordination schedule, and the file format you need (Revit, Navisworks, or SprinkCAD). Tell us who is running coordination and whether you need us to model, clash, attend meetings, or all three.
Why it matters: Modeling to the wrong level of development, or joining a coordination cycle late, means rework and missed clash deadlines. Clear expectations let BIM coordination start at the right depth and stay on the GC's calendar.
Be clear about the schedule
Give us the bid date, the date you need a permit set or shop drawing submittal, the construction start, and any phasing. If the engineer of record or the AHJ has a review cycle, build that into the timeline from the start. Tell us who will review the set, and how you want markups handled (Bluebeam, Procore, or email).
Why it matters: A firm delivery date only works if the due date is real and the review path is known. Hidden submittal gates are how a "quick set" misses the window.
Depending on project scope and size, plans can be ready in as little as 24 hours. Every quote includes a fixed price and a firm delivery date.
The handoff checklist
Send what you have. If an item isn't available yet, note that instead of leaving it out.
- Current architectural, structural, and MEP backgrounds (CAD or Revit, with software and version), plus PDFs
- Reflected ceiling plans, ceiling heights, and known obstructions
- NFPA 13, 13R, or 13D, the adopted edition, and local amendments
- Occupancy and hazard classification; for storage, commodity, height, and rack data
- Flow test: static pressure, residual pressure, flow, date, and location
- AHJ name and any insurance requirements, including FM Global
- Whether the AHJ wants Tier 1 permit plans or full shop drawings
- Existing-system drawings, calculations, and photos for TIs and renovations; if conditions are unknown, we can do a site survey
- Preferred pipe, fittings, hangers, and heads, plus fab shop and CAD standards
- BIM execution plan, level of development, and coordination schedule, if the job is modeled
- Bid, submittal, and construction dates, including the review path
Ready to hand off a job?
Send your plans and this information to quotes@natlfsd.com, or request a quote. We'll come back with scope, price, and a delivery date.
National Fire Sprinkler Design is a nationwide, design-only firm for fire sprinkler contractors.